Online Electrochemical H2S Gas Analyzer for CEMS Application

Online Electrochemical H2S Gas Analyzer for CEMS Application
www.gasese.com
Online Electrochemical H2S Gas Analyzer can be used for measurement of the concentration of H2S in sample gases simultaneously . It is based on the fuel cell method (ECD) for H2S. This analyzer is designed with 19 inches 3U smaller physical dimensions .The general application is  for CEMS application with 0-100ppm range.



Operating Principle
3-electrode potentiostatic cell w/o potentiostat
Sensor Lifetime
~ 2 years
Measurement Range
0 to 100 ppm
Maximum Overload
up to 250 ppm
Sensitivity
500 to 1,000 nA/ppm
Response Time t90
< 25 s
Drift
< 30 % signal/year
Zero Offset Current
< ± 1 ppm
Bias Voltage
+ 300 mV
Warm-up Time
8 h, when connected to Bias
Operating Temperature
10 to 45 °C(increased response time below 0 °C)
Pressure Range
750 to 1250 hPa
Humidity Range
30 to 60 % RH
Interferences
(without filter)
2.000 ppm CO: < 1 nA/ppm
1.000 ppm SO2: < 40 nA/ppm
800 ppm NO: < 400 nA/ppm
100 vol. % H2: none



Output Interface
RS232
Analog output
420mA
Working Temperature
1045℃
Relative Humidity
3060%
Pressure
750 to 1250 hPa
Power supply
200V-240V AC / 50Hz-60Hz  (100-120V AC/ 50-60Hz optional)
Temperature control
55℃
Calibration
Zero and span calibration
Dimensions
435*450*135 mm (L*W*H)
Weight
About 12kg