2016年12月6日星期二

Online Electrochemical H2S Gas Analyzer for CEMS Application


Operating Principle
3-electrode potentiostatic cell w/o potentiostat
Sensor Lifetime
2 years
Measurement Range
0 to 100 ppm
Maximum Overload
up to 250 ppm
Sensitivity
500 to 1,000 nA/ppm
Response Time t90
< 25 s
Drift
< 30 % signal/year
Zero Offset Current
< ± 1 ppm
Bias Voltage
+ 300 mV
Warm-up Time
8 h, when connected to Bias
Operating Temperature
10 to 45 °C(increased response time below 0 °C)
Pressure Range
750 to 1250 hPa
Humidity Range
30 to 60 % RH
Interferences
(without filter)
2.000 ppm CO: < 1 nA/ppm
1.000 ppm SO2: < 40 nA/ppm
800 ppm NO: < 400 nA/ppm
100 vol. % H2: none
Output Interface
RS232
Analog output
420mA
Working Temperature
1045℃
Relative Humidity
3060%
Pressure
750 to   1250 hPa
Power supply
200V-240V AC / 50Hz-60Hz  (100-120V AC/ 50-60Hz optional)
Temperature control
55℃
Calibration
Zero and span calibration
Dimensions
435*450*135 mm (L*W*H)
Weight
About 12kg