Specifications
| |||||||||
Gas
|
Range
|
Resolution
|
Repeatability
|
Linearity
|
Response time
|
Drift
| |||
O2
|
0-10%vol(can be customized)
|
0.1%
|
≤1%FS
|
≤1%FS
|
≤2S
|
≤±1%FS
| |||
Warm up
|
30min
|
Digital output
|
RS232/485
|
Analog output
|
4-20mA
| ||||
Power supply
|
DC18-36V/20W or
AC100-240V/47-63Hz
|
Relay output
|
Load capacity: AC/DC 4V/1A; Concentration limitation alarm, abnormal transmittance alarm, abnormal laser temperature alarm
| ||||||
Optical path
|
1-12m
|
Flue gas temperature
|
≤1100℃
|
Flue gas pressure
|
Atmosphere pressure±5kPa
| ||||
Dust content
|
≤10000mg/Nm3
|
Protection level
|
IP65
|
Explosion level
|
ExdIICT5(optional)
| ||||
Flushing gas
|
Industrial N2 gas >0.3MPa
|
Ambient temperature
|
-10~55℃
|
Ambient pressure
|
70kPa-120kPa
| ||||
2016年12月21日星期三
Extractive Oxygen Laser Gas Analyzer
Extractive Oxygen Laser Gas Analyzer
Features
- high integration design, compact structure, simple installation and maintenance
- no sample pretreatment needed, real-time measurement of oxygen concentration
- single spectra scan, no interference from dust, tar and background gases
- maintenance-free design
- optional explosion-proof design
Applications
- process control/explosion pre-warning monitoring
- environmental flue gas emission monitoring
- boiler combustion control
- air separation and gas production
- aerospace, electric power, electronics, biological technology and scientific research institutions, etc
2016年12月6日星期二
Online Electrochemical H2S Gas Analyzer for CEMS Application
Operating Principle
|
3-electrode potentiostatic cell w/o potentiostat
|
Sensor Lifetime
|
~ 2 years
|
Measurement Range
|
0 to 100 ppm
|
Maximum Overload
|
up to 250 ppm
|
Sensitivity
|
500 to 1,000 nA/ppm
|
Response Time t90
|
< 25 s
|
Drift
|
< 30 % signal/year
|
Zero Offset Current
|
< ± 1 ppm
|
Bias Voltage
|
+ 300 mV
|
Warm-up Time
|
8 h, when connected to Bias
|
Operating Temperature
|
10 to 45 °C(increased response time below 0 °C)
|
Pressure Range
|
750 to 1250 hPa
|
Humidity Range
|
30 to 60 % RH
|
Interferences
|
(without filter)
2.000 ppm CO: < 1 nA/ppm
1.000 ppm SO2: < 40 nA/ppm
800 ppm NO: < 400 nA/ppm
100 vol. % H2: none
|
Output Interface
|
RS232
|
Analog output
|
4~20mA
|
Working Temperature
|
10~45℃
|
Relative Humidity
|
30~60%
|
Pressure
|
750 to 1250 hPa
|
Power supply
|
200V-240V AC / 50Hz-60Hz (100-120V AC/ 50-60Hz optional)
|
Temperature control
|
55℃
|
Calibration
|
Zero and span calibration
|
Dimensions
|
435*450*135 mm (L*W*H)
|
Weight
|
About 12kg
|
Online Electrochemical H2S Gas Analyzer for CEMS Application
Operating Principle
|
3-electrode potentiostatic cell w/o potentiostat
|
Sensor Lifetime
|
~ 2 years
|
Measurement Range
|
0 to 100 ppm
|
Maximum Overload
|
up to 250 ppm
|
Sensitivity
|
500 to 1,000 nA/ppm
|
Response Time t90
|
< 25 s
|
Drift
|
< 30 % signal/year
|
Zero Offset Current
|
< ± 1 ppm
|
Bias Voltage
|
+ 300 mV
|
Warm-up Time
|
8 h, when connected to Bias
|
Operating Temperature
|
10 to 45 °C(increased response time below 0 °C)
|
Pressure Range
|
750 to 1250 hPa
|
Humidity Range
|
30 to 60 % RH
|
Interferences
|
(without filter)
2.000 ppm CO: < 1 nA/ppm
1.000 ppm SO2: < 40 nA/ppm
800 ppm NO: < 400 nA/ppm
100 vol. % H2: none
|
Output Interface
|
RS232
|
Analog output
|
4~20mA
|
Working Temperature
|
10~45℃
|
Relative Humidity
|
30~60%
|
Pressure
|
750 to 1250 hPa
|
Power supply
|
200V-240V AC / 50Hz-60Hz (100-120V AC/ 50-60Hz optional)
|
Temperature control
|
55℃
|
Calibration
|
Zero and span calibration
|
Dimensions
|
435*450*135 mm (L*W*H)
|
Weight
|
About 12kg
|
2016年12月1日星期四
In-situ Oxygen Laser Gas Analyzer iLAS-100
Specifications
| |||||||||
Gas
|
Range
|
Resolution
|
Repeatability
|
Linearity
|
Response time
|
Drift
| |||
O2
|
0-10%vol(can be customized)
|
0.1%
|
≤1%FS
|
≤1%FS
|
≤2S
|
≤±1%FS
| |||
Warm up
|
30min
|
Digital output
|
RS232/485
|
Analog output
|
4-20mA
| ||||
Power supply
|
DC18-36V/20W or
AC100-240V/47-63Hz
|
Relay output
|
Load capacity: AC/DC 4V/1A; Concentration limitation alarm, abnormal transmittance alarm, abnormal laser temperature alarm
| ||||||
Optical path
|
1-12m
|
Flue gas temperature
|
≤1100℃
|
Flue gas pressure
|
Atmosphere pressure±5kPa
| ||||
Dust content
|
≤10000mg/Nm3
|
Protection level
|
IP65
|
Explosion level
|
ExdIICT5(optional)
| ||||
Flushing gas
|
Industrial N2 gas >0.3MPa
|
Ambient temperature
|
-10~55℃
|
Ambient pressure
|
70kPa-120kPa
| ||||
In-situ Oxygen Laser Gas Analyzer iLAS-100
Features
- high integration design, compact structure, simple installation and maintenance
- no sample pretreatment needed, real-time measurement of oxygen concentration
- single spectra scan, no interference from dust, tar and background gases
- maintenance-free design
- optional explosion-proof design
Applications
- process control/explosion pre-warning monitoring
- environmental flue gas emission monitoring
- boiler combustion control
- air separation and gas production
- aerospace, electric power, electronics, biological technology and scientific research institutions, etc
订阅:
评论 (Atom)