coal chemical process
steel making process as blast furnace, converter, coking, direct iron ore smelting reduction
syngas production from Biomass and coal gas gasification processes
Heat treatment
Measurement technology
•Infrared dual beam NDIR for CH4,CO2,CO,CnHm
•Thermal conductivity TCD for H2
•Galvanic fuel cell ECD for O2
•Gas calorific value :calculated
Min/Max available range
•CH4,CO2,CO,H2:0-10%/0-100%
•CnHm:0-10%
•O2”0-5%/0-100%
•Intermediary ranges available without price increase
•Resolution: 0,01%
•Accuracy: ≤ 2% FS
•Repeatability: ≤ 1% FS
•Response time: NDIR/ECD < 10 sec / TCD < 15 sec
•Warm-up time: 800 seconds
•Gas conditions at inlet
•Quality: no dust, tar, oil, water vapor and/or moisture
•Pressure : 2 to 50 Kpa
Standard features
·Proprietary infrared dual beam NDIR detectors for CH4, CnHm, CO and CO2
·Proprietary thermal conductivity detector for H2
·Industrial galvanic fuel cell for O2 (0-25%)
·Calculation and display of the BTU index (gas calorific value, only with SYNGAS analysers)
·LCD display (240 x 128) with backlit function
·Keyboard interface for configuration and calibration
·1x 4-20mA output per measuring channel
·2 alarm relays per measuring channel, with 2 freely configurable gas alarm levels
·RS232 serial COM port (for real time data download to external PC or laptop as text file, software included)
·Programmable auto-zero function, including internal pump, relay and solenoid valve
·Stainless steel connectors for gas inlet/outlet and zero air inlet ports
Gas analysis systems are the best tooling to help you:
to check whether the gas is still being produced to decide when the land can be reclaimed.
to check the quality of the gas being produced prior to use in some industrial process.
To continuously monitor the efficiency of H2S scrubber installations