| Measurement | CO, CO2, CH4, CnHm, O2, H2 + BTU index (gas calorific value) |
| Calculation | High Heating Value or Low Heating Value in MJ/m3 or kcal/m3
N2(Optional)
|
| Technology | CO, CO2, CH4, CnHm: proprietary dual beam NDIR detectors
O2 : industrial electrochemical cell
H2 : proprietary thermal conductivity detector
|
| No effect of CO2 and CH4 on H2 detector | H2 reading is compensated for the interference effects of the other gases measured |
| Resolution | 0,01% |
| Accuracy | ≤ ± 2% FS |
| Repeatability | ≤ 2% |
| Zero | Auto-zeroing function via keyboard interface |
| Gas conditions at analyzer inlet | Flow:0.7~1.2L/min, internal gas sampling pump, external flow meter with needle valve
Pressure:20~100mbar
Quality: No dust, moisture, tar (external safety filter and optional gas washing unit)
|
| Operating conditions | Tamb : 0-50°C / Pamb : 86 to 108 kPa / RH : 0-95% non condensing |
| Response time (T90) | ≤ 15 sec |
| Warm-up time | 800 seconds (auto-zeroing cycle during the last 120 seconds) |
| Communication interface | RS232 ( real time and memory data download software included) |
| Power supply | External 220 VAC-50Hz |
| Internal with battery and charger; Autonomy of > 4h with pump in operation | |
| Data logging | Up to 1500 sets of data; Logging rate adjustable from 3 to 99 sec
Possibility to identify 10 different sites and up to 100 measuring points
|
| Display | LCD 320 x 240 display with back-lit function
Simultaneous indication of the 7 measures and units
|
| Casing | New design moulded casing and shoulder trap (delivered with protective carrying bag) |
| Casing | Robust casing in aluminium with cover and shoulder trap |
| Dimensions and weight | Gas analyser: W415 × D150 × H285 mm |
| Portable gas washing unit : L400 x D120 x H 380 mm / ± 3 kg (5 kg max with packaging) |